XO2TCuZ1-K (AS+) is a very flexible fireproof shielded instrument cable for fixed installation on marine vessels. The cable is particularly suitable for installations in which EMC shielded cables are required. The cable is halogen free, with low smoke emission and fire retardant.
Electrolytic tinned annealed Cu, class 5 acc. to IEC 60228
Mica tape + halogen free XLPE
Twisted pair (blue/white)
Collective screen of Aluminium/Polyester tape with a tinned Cu drain wire. Tinned Cu wire braid armour over the collective screen
LSZH thermoplastic polyolefine SHF1, orange
-40° C to +90° C
150/250 V
≤ 25 mm: 4 x cable diameter
≥ 25 mm: 6 x cable diameter
IEC 60331-2/EN 50200 for Ø < 20 mm
IEC 60331-1/EN 50362 for Ø > 20 mm
Short circuit temperature: max 250° C / 5 sec.
SKU | EAN | Dimension (mm2) | Current Value (A) | Winding | Diameter (mm)* | Weight (kg/km)* | |
---|---|---|---|---|---|---|---|
662012075 | 5704403085613 | 1x2x0,75 | 17,1 | D./Cut | 10,5 | 145 | |
662022075 | 5704403085620 | 2x2x0,75 | 13,7 | D./Cut | 14,3 | 230 | |
662042075 | 5704403085637 | 4x2x0,75 | 11,2 | D./Cut | 18,1 | 375 | |
662072075 | 5704403087846 | 7x2x0,75 | 9,2 | D./Cut | 21,0 | 605 | |
662242075 | 5704403207466 | 24x2x0,75 | 6,5 | D./Cut | 31,3 | 945 | |
* The values can have small deviations |