SCANLET PLUS ® Ultra light

Application

SCANLET PLUS® Ultra light installation cables are used in fixed installations, which require the use of environmentally friendly halogen free cables. They can be used in dry and humid areas both indoor and outdoor, built into walls, embedded, or buried in the ground. Conductor insulation is not suitable for direct light exposure. 

SCANLET PLUS® Ultra light is registered in the database for construction products that can be used in the Nordic Ecolabelled (Svanen) construction. 

Construction

Conductor

Single-threaded Cu, class 1 

Insulation

XLPE

Conductor color

3 conductors: blue, brown, yellow/green
5 conductors: brown, black, grey, blue, yellow/green

Outer sheath

Polyolefin, meter marked, light grey RAL 9002

Technical data

Working temperature

Fixed installation: -15° C to +90° C

Rated voltage

1,5 mm² and 2,5 mm²: 300/500 V
5G4 mm², 5G6 mm² and 4x10 mm²: 0,6/1 kV

Test voltage

1,5 mm² and 2,5 mm²: 2000 V
5G4 mm², 5G6 mm² and 4x10 mm²: 4000 V

Bend radius

1,5 mm² and 2,5 mm²: 10 x cable diameter
5G4 mm², 5G6 mm² and 4x10 mm²: 12 x cable diameter

Technical comments

Conductor resistance:
1,5 mm²: 12,1 Ω/km
2,5 mm²: 7,41 Ω/km
5G4 mm²: 4,61 Ω/km
5G6 mm²: 3,08 Ω/km
4x10 mm²: 1,83 Ω/km

CPR classification:

Dca-s1,d2,a1 / Eca

Please request for DoP at dop@scankab.dk

Approvals

EN 50575, IEC 60332-1, IEC 60228, EN 60754, IEC norms low voltage, CE, RoHS
Bending radius 10 x cable diameter
Can be buried
Can lay in tubes
Environmentally friendly
Flame retardant acc. to IEC 60332-1
For permanent outdoor installation
For use in cable trays
For use in homes
Halogen free
Low smoke emission during fire acc. to 61034
Low voltage cable
Max. working temp. +90° C
Meter marked
Min. working temperature -15° C
Outdoor use
Suitable for bricking
Suited for public places
Suited for wall attachment
UV-resistant
UV-stabilized
Withstands freezing
SKU EAN CPR Dimension (mm2) Current Value (A) Winding Diameter (mm)* Weight (kg/km)*
122415003 5704403189359 Eca 3G1,5 23,0 R-100 7,7 110
122415013 5704403189434 Eca 3G1,5 23,0 T-500 7,7 110
122415013X 5704403189397 Eca 3G1,5 23,0 R-300 7,7 110
122415005 5704403189373 Eca 5G1,5 23,0 R-100 8,8 154
122415015 5704403189441 Eca 5G1,5 23,0 T-500 8,8 154
122415005X 5704403189410 Eca 5G1,5 32,0 T-250 8,8 154
122425003 5704403189366 Eca 3G2,5 32,0 R-100 8,6 151
122425013 5704403189458 Eca 3G2,5 32,0 T-500 8,6 151
122425013X 5704403189403 Eca 3G2,5 32,0 T-250 8,6 151
122425005 5704403189380 Eca 5G2,5 32,0 R-100 10,2 216
122425015 5704403189465 Eca 5G2,5 32,0 T-500 10,2 216
122425015X 5704403189427 Eca 5G2,5 32,0 T-200 10,2 216
120004025H 5704403169054 Dca-s1,d2,a1 5G4 42,0 D./Cut 13,0 450
120006025H 5704403059935 Dca-s1,d2,a1 5G6 53,0 D./Cut 16,5 600
120010024H 5704403059997 Eca 4x10 74,0 D./Cut 18,0 670
* The values can have small deviations