PROFINET Bus P 3110 - 30 V

Application

PROFINET cables for fixed and flexible installation. 

PROFINET cable - "Fast Connect" type - for fixed installation uses standard Ethernet, TCP and UDP protocols for net transmission, configuration and control, according to Cat. 5 transmission requirements. 

Construction

Conductor

Bare copper according to CEI EN 60228 (CEI 20-29)

Insulation

Polyolefin

Conductor color

Yellow, white, orange, blue

Inner sheath

TPE compound

Screen

Tinned copper wire braid.
Coverage above 85%.
Aluminium/polyester tape.

Outer sheath

PUR according to UL 1581 and C22.2 no 210. 
Colour: green RAL 6018

Technical data

Working temperature

Fixed installation: -30oC to +80oC
Flexible installation: -5oC to +80oC

Rated voltage

30 V

Test voltage

1000 V

Bend radius

Fixed installation: 5 x cable diameter
Flexible installation: 10 x cable diameter

Approvals

CEI EN 60228, UL 1581, IEC CEI EN 60332-1, ≤0,5% IEC 60754, CEI EN 50267-2, EN 50363-10-2, CE
Bending radius 5 x cable diameter
Electromagnetically protected
Flame retardant acc. to IEC 60332-1
Low emission of corrosive gases acc. to IEC 60754
Max. working temp. +80° C
Min. working temperature -30° C
Oil resistant
Suitable for cable chains
Water resistant
SKU EAN Dimension (mm2) Current Value (A) Winding Diameter (mm)* Weight (kg/km)*
386004003 5704403076208 1x4xAWG22/19 - D./Cut 6,7 68
* The values can have small deviations